13 Pump OIL DATA
WARNING!
It is important for the pump oil (specific for food vacuum applications and FDA certified) to
always be kept in optimal conditions: fluid and clean, i.e. free from grit and watery parts.
Check the oil level periodically: if the vacuum machine is used in catering or restaurant sector, the pump
dehumidification cycle must be performed daily, at the end of working day. In other cases, it must be
performed at least weekly
1) The oil must be changed according to the workload, in any case every 6 months, or once the number of
cycles programmed has been reached and on the machine display appears OIL.
Contact the service center to perform the oil change.
At every oil change, replace the exhaust filter, too.
2) It is necessary to change oil before an inactivity time longer than two months. Doing so, all oxidized
residues and liquids, remained in the oil tank during the inactivity time, will be drained together with the
exhaust oil.
3) The room temperature should not fall below than +10°C, to avoid the pump oil thickening. Better oil fluidity
facilitates the starting of cold pump.
14 scheduled routine maintenance
Implementing the scheduled maintenance regularly, as described further on in this manual, minimises
and/or eliminates potential faults and interference and increases the machine lifetime significantly.
Failure to perform regular maintenance can lead to significant repair costs, and in certain cases, render the
guarantee null and void. Furthermore, respecting the recommendation, a good hygienic level is
guaranteed.
To carry out cleaning and routine maintenance operations safely, follow the regulations listed below:
ELECTRICAL HAZARD! If the power supply cable is damaged, it must be replaced.
ELECTRICAL HAZARD! The power sources must be disconnected before cleaning, disinfecting,
performing maintenance and/or repairing any component of the appliance (Disconnect the
electrical plug from the mains).
DANGER! It is strictly prohibited to remove the guards and safety devices to perform routine
maintenance. Orved S.p.A. declines all liability for accidents due to non-compliance with
the above-mentioned obligation.
WARNING!
Always use suitable preventive measures and protective devices (gloves, etc.) for any
maintenance, handling, installation and cleaning operations.
WARNING! Only qualified technicians must perform maintenance or access live parts of the
machine.
Contact a Technical Support C entre authorised by the manufacturer for any repairs. Only original
spare parts must be used and requested.
Do not perform maintenance yourself where the intervention of a qualified technician is indicated
in the manual.
Do not touch the machine with bare, damp or wet hands or feet.
Do not insert screwdrivers, kitchen instruments or anything similar between the guards, openings
and moving parts of the machine,
After completing the work, detach the piston by pushing it toward the rear and lower the lid to
the resting position. This protects the vacuum chamber from dust and dirt.
_______________________________________________________________________________________
ORVED S.P.A Rev.01 – 09/2019 – cod. 1500735-00EN – User Manual for
IDEA
vacuum packing machines
Pag. 57 a 76
MACHINE PART INTERVENTION
FREQUENCY INTERVENTION PERFORMED
1-G 1-S 6-M 1-A 4-A USER
SERVICE
CENTER
Pump
Check the oil level and colour;
top-up if necessary or replace, if
the colour is too dark or whitish
(contact a specialised service
centre).
X O
Oil top-up or
replacement.
Pump
Operate a pump heating cycle
for at least 5 minutes, or a pump
dehumidification cycle.
X O
Power cord
Verify its integrity; replace
if defective
X O Replacement
Plexiglass lid
Verify its integrity; if there are any
cracks or streaks, contact the
after-sales centre to
replace the lid.
X O Replacement
Upper bar
silicone and
Plexiglass lid
gasket
Check that they are inserted well
into the respective seats; replace
if defective or worn.
X O Replacement
Machine and
vacuum
chamber
Clean impurities, oil and grease. X O
Sealing bar
connection
Check that it is inserted well on
to the two contact pins.
X O
Pump
Run a pump dehumidification
cycle.
X X O
Sealing bar
Clean the upper part with a
damp cloth.
Clean the two contact pins.
X O
Machine,
vacuum
chamber, lid
and fillers.
Sanitize X O
Pump Replace the pump oil X O
Pump Replace the oil filter X O
Pump
Change the oil and replace the
oil filter before a long inactivity
(time longer than 2 months)
The present intervention has
to be performed before a
long inactivity period
O
15 TROUBLESHOOTING
ERRORE PROBLEM POSSIBLE CAUSES SOLUTION
1
Machine not working.
Machine off
Switch the machine on (press
STOP button for 5”)
No power supply
Insert the plug in a socket
(check the voltage!).
• Check power cable to make
sure it is intact.
Check fuse PF1 on the
power board to make sure
they are intact and inserted
correctly (contact a service
centre).
Machine damage Contact the authorised
service center
2
Insufficient vacuum in the
bag/bag does not maintain
vacuum.
Bag Incorrectly positioned
Place the bag centrally on
the sealing bar overpassing it
about 20 mm.
Bag perforated
Choose a thicker bag and
wrap the product
with cling film or soft paper.
Insufficient sealing Increase the sealing time