8
Pressing STOP button at any time, it is possible
to interrupt the vacuum cycle immediately
and the vacuum chamber is uncompressed.
The lid opens automatically.
The machine comes back to the selected
program.
9
End of cycle. The lid opens automatically. Remove the container.
9.5.4 Containers external
Phase
Description Image
1
(A)
to operate the vacuum in containers externally, both in the vacuum
chamber and on the container lid. Make sure that the air intake device be open.
2
Activate the command panel by double
quick touch on the screen.
Press the STAND-BY button, to turn the
machine on.
3
Select Jars Cycles.
4
Select the desired program choosing between: Editable Cycle, MIN Level, MED Level, MAX
Level.
JARS CYCLE
_______________________________________________________________________________________
ORVED S.P.A Rev.01 – 09/2019 – cod. 1500735-00EN – User Manual for
IDEA
vacuum packing machines
Pag. 51 a 76
5a
In case an Editable Cycle is chosen, set the
required vacuum level, then press START to
start it.
5b
In case a Preset Cycle (MIN Level, MED
Level, MAX Level) is chosen, press START to
start it.
6
1) In case the set vacuum level is lower
than 99%, the pump switches off.
Remove the accessory, place it on the lid of
next container and press START to start a
new cycle.
2) In case the set vacuum level is 99%, the
pump remains on.
Remove the accessory and place it on the
lid of next container.
7
Pressing STOP button at any time, it is possible
to interrupt the vacuum cycle immediately.
8
At the end of vacuum cycle, remove the accessory from the chamber.
9.6 ALARM management
9.6.1 IDEA 30 – 40 e IDEA 31 – 41
CAUTION!
In case the number of allowed cycles (preset in the machine) has been reached, at every switch-
on the machine displays the pump oil change alarm “OIL”.
ICON OR
MESSAGGE
DESCRIPTION
ALL OIL
Change the oil
: the alarm appears when the 5.000 vacuum cycles have been
operated.
ALL GAS
Gas failure
: the alarm appears when the machine detects anomalies in inert GAS
inlet system.
JARS CYCLE
JARS CYCLE MIN
JARS CYCLE
JARS CYCLE