_______________________________________________________________________________________
ORVED S.P.A Rev.01 – 09/2019 – cod. 1500735-00EN – User Manual for
IDEA
vacuum packing machines
Pag. 74 a 76
19 TECHNICAL DATA
19.1
Idea 30 – idea 40
TECHNICAL DATA IDEA 30 IDEA 40
Weight (with 2 black plates)
Maximum absorbed power DVP pump 600W 800W
Vacuum chamber dimensions
Maximum bag size mm 300x350 400x450
Pump mode/flow rate [m
3
/h]
DVP
Room temperature of use °C 12 ÷ 40
Relative humidity in usage room % 10 ÷ 80
19.2
Idea 31 – idea 41
TECHNICAL DATA
IDEA 31 IDEA 41
Weight (with 2 black plates)
Power supply voltage V 230/ 50-60Hz 230/ 50-60Hz
Maximum absorbed power DVP pump 700W 900W
Vacuum chamber dimensions
Sealing bar length mm 310 410
Pump mode/flow rate [m
3
/h]
DVP
Room temperature of use °C 12 ÷ 40
Relative humidity in usage room % 10 ÷ 80
19.3 Idea 32
Hi-Line
– idea 42
Hi-Line
TECHNICAL DATA
Idea 32
Hi-Line
Idea 42 Hi-Line
Weight (with 2 black plates)
Power supply voltage V 230/ 50-60Hz 230/ 50-60Hz
pump
600W 1200W
Vacuum chamber dimensions
Sealing bar length mm 310 410
Maximum bag size mm 300x400 400x450
Pump mode/flow rate [m
3
/h]
DVP
Room temperature of use °C 12 ÷ 40
Relative humidity in usage room % 10 ÷ 80
_______________________________________________________________________________________
ORVED S.P.A Rev.01 – 09/2019 – cod. 1500735-00EN – User Manual for
IDEA
vacuum packing machines
Pag. 75 a 76
20 WARRANTY
It is standard for all ORVED products to be subjected to severe quality and functional tests before installation
to protect and safeguard Client interests.
Coverage
ORVED guarantees its products against all manufacturing and processing defects and undertakes to replace
any parts found to be defective by the manufacturer, free of charge.
Duration
ORVED guarantees its products for professional use, fora period of 12 (twelve) months from the sale date
shown on the purchase document.
General terms
ORVED warranty terms:
a) The warranty covers only the free replacement of components found to be defective by ORVED or any
of its authorised representatives.
b) ORVED liability is limited to the sole replacement of parts found to be defective; under no circumstances
shall ORVED respond
to claims for compensation of any other type.
c) Disputed and/or defective products shall be returned to ORVED and all transport expenses for the
delivery of parts shall be
entirely borne by the Client.
d) Normal wear and tear of components is not covered by the warranty.
e) The warranty period shall not be extended following repairs.
Invalidation of warranty
In addition to the natural expiry of the warranty period, the warranty shall be considered null and void in the
following cases:
a) Tampering with, alteration in any way or removal of the appliance's identification plate, without Orved
S.p.A. having been promptly notified.
b) Changes made to the device or its parts without the prior written consent of Orved S.p.A. In addition to
invalidating the warranty, any tampering with the device or its parts shall relieve Orved S.p.A. of all liability
for any injury/damage to persons, animals or property.
c) Failure to follow the instructions in this manual.
d) Use of the appliance for purposes different to those specified in this manual.
e) Damage or accidents suffered by the appliance caused by external factors.
f) Use, repairs and/or maintenance of the appliance by non-specialised personnel.
21 Useful notes
Purchasing date: ___________________________________________________________________________
Dealer:
Company name: ____________________________________________________________________________________
Address: __________________________________________________________________________________
Telephone: __________________________________________________________________________________
Fax: ______________________________________________________________________________________