_______________________________________________________________________________________
ORVED S.P.A Rev.01 – 09/2019 – cod. 1500735-00EN – User Manual for
IDEA
vacuum packing machines
Pag. 14 a 76
5
Put the vacuum bag (C) containing the
product to be packed, in the vacuum
chamber (B) and place it centrally on the
sealing bar (D). The fringe, no wrinkles, has to
overpass the sealing bar about 2cm.
Do not bend downwards the bag exceeding
the sealing bar.
Idea 31 – 41: in case the gas injection is
required, insert the gas nozzle in the bag
open part (E).
6
Select one of the 10 programs P1 – P10, using
UP/DOWN buttons.
7
Press SEL/OK to select the parameter
Vacuum and press UP/DOWN to set a value
between 10% and 99%.
Any vacuum level lower than the maximum,
reduces or cancel the preservation effect,
due to the residual air remained in the bag.
8
If the vacuum was set to 99%, then press
UP/DOWN buttons again to set the additional
vacuum level between 1” and 60”.
9
Idea 31 – 41: Press SEL/OK button to select
GAS parameter and UP/DOWN buttons to
set a value between 1% and 90%.
When the GAS function is active, make sure
that the vacuum level set is 99%.
10
Press SEAL button to set the sealing time
between 0,1” and 6,0”, depending to the
vacuum bag in use.
_______________________________________________________________________________________
ORVED S.P.A Rev.01 – 09/2019 – cod. 1500735-00EN – User Manual for
IDEA
vacuum packing machines
Pag. 15 a 76
11
Lower the lid using both hands, by pressing on
the corners.
The vacuum cycle starts automatically.
12
Press SEL/OK button to switch in advance
from Vacuum phase to GAS phase (only on
Idea 31 – 41),
Press SEL/OK to advance the GAS phase,
verifying that the vacuum threshold of 90%
was reached. Otherwise, the sealing will be
activated.
Press SEAL button to switch in advance to
sealing.
13
Pressing STOP button at any time, it is possible
to interrupt the vacuum cycle immediately
and the vacuum chamber is uncompressed.
The lid opens automatically.
The machine comes back to the selected
program.
14
End of cycle. The lid opens automatically.
Remove the packed products, paying attention not to touch the sealing bar, as it may be still
hot.
In case of packing liquid products, fill the bag no more one-third of its volume; if the optional “sloping shelf
for liquids” is available, adjust it according to the bag size.
Turn the machine on and proceed in setting the parameters, as described in the chart above, adjusting the
vacuum level, in order to avoid any liquid overflowing.
Lower the lid using both hands, by pressing on the corners. The vacuum cycle starts automatically.