Section 4 Operation
4 - 12
May 1992
MX-5050 Operation and Maintenance Manual
4.5.3 Search Play Mode
To enter Search Play mode, press the PLAY button while in Search mode. The
Lamp on the PLAY button will flash, and the MX-5050 will enter Play mode
when the tape reaches the Cue Point.
4.5.4 Search Zero Mode
To enter Search Zero mode, press the SEARCH ZERO button. The tape will
move at Fast Wind speed to the location corresponding to 0:00:00 on the
Tape Time display and stop. During the Search the indicator in the SEARCH
ZERO button will flash.
4.5.5 Search Start Mode
When SW2-1 on the Transport Control PCB Assembly is in the On position
and SW2-2 is in the Off position, the Search Start function is assigned to the
SEARCH 3 key.
In this mode, whenever the PLAY button is pressed, that location is stored in
Cue Point memory 3. Pressing the SEARCH 3 key moves the tape to the point
where the PLAY button was last pressed.