Regenerative
braking torque
100% or more (Short-time)
DC braking
Operates when less than stop frequency
䊶Braking torque level: 0 to 100 (set between 20 levels)
䊶Braking time: Optional setting for 0.1 to 120s
With
brakes
Without
brakes
80% or more
Braking
Start/stop
䊶Operation panel buttons
䊶Control terminal input signal (OPEN signal, CLOSE signal)
䊶Communication command (RS485)
Frequency setting signal
䊶Operation panel setting
䊶Door operation mode setting
䊶Communication command (RS485)
Accel./decel. time
0.04 to 999s (individual acceleration and deceleration setting)
Door operation mode setting
䊶OPEN/CLOSE operation frequency: Max.6 speed can be set.
䊶Accel./decel. time: Set OPEN and CLOSE operation frequency respectively.
䊶Door speed change position: Up to 5 place settings
䊶Door hold frequency: 1 speed (individual OPEN and CLOSE setting)
䊶Door hold torque: Hold current setting ( individual OPEN and CLOSE setting)
Stop mode
Select from ramp-to-stop or coast-to-stop (selection changeover)
Accel./decel. characteristics
Linear and S-shaped characteristics (selection changeover)
Stop frequency
Optional setting from 0.5 to 60Hz.
Control
Skip frequency setting
Up to 3 place settings
(skip frequency band setting from 1 to 10Hz)
Ride-through function
Validity of function, and 0Hz restart, operating frequency
restart (selection changeover)
Upper frequency clamp setting
Optional setting from 0.5 to 250Hz.
Lower frequency clamp setting
Optional setting from 0.5 to 250Hz.
Retry function
Retry selection : Select validity of function and details of retry fault
Retry times: Optional setting for 1 to 10 times
Reset function Stop signal reset, panel reset and power supply reset.
Door control function
䊶Door speed control in encoder mode
䊶Door speed control in SW (switch) mode.
䊶Door width measurement function
䊶Door obstacle detection function
96