JOG Positioning Operation FP Positioning Unit
9-14
9.3 Operation of the Input and Output Flag at JOG
Positioning Operation
JOG positioning operation start flag(Y_8)
1. JOG positioning operation is initiated based on the parameters written to the positioning unit.
2. JOG positioning operation is not initiated during the time that the pulse output busy flag (X_0) is ON.
already initiated.
3. JOG positioning operation start flag is reset when the power supply is turned OFF.
Pulse output busy flag(X_0)
1. This goes ON with the next scan after JOG positioning operation has been initiated, and goes OFF
when the pulse output is completed.
2. Operation cannot be shifted to any other operation while this signal is ON (except for a forced stop
and a deceleration and stop).
3. This flag is reset when the power supply is turned OFF.
-This flag is shared among E point control, P point control, JOG operation, JOG positioning operation
and home return. (except for a pulser input enabled operation)
Pulse output done flag(X_0)
1. This goes ON when the pulse output is completed, and is maintained until the next E point control, P
point control, JOG operation, JOG positioning operation, home return, or pulser input enabled status
is initiated.
2. This flag is reset when the power supply is turned OFF.
-This flag is shared among E point control, P point control, JOG operation, JOG positioning operation
and pulser input enabled operation.