Home Return FP2 Positioning Unit
10-24
10.7 Operation at Over limit Input
Home return operation is as follows when Over limit input (+) or Over limit input (-) is ON.
The operation in the direction in opposite to the input limit is possible.
Home Return (without home search)
Condition Direction Limit status Operation
Over limit input (+):ON
Table not to move,
Limit error occurs.
Forward
Over limit input (-):ON
Table to move
Over limit input (+):ON
Table to move
When Home return is
turned ON
Reverse
Over limit input (-):ON
Table not to move,
Limit error occurs.
Forward
Over limit input (+):ON
Table stops,
Limit error occurs.
During Home return
operation
Reverse
Over limit input (-):ON
Table stops,
Limit error occurs.
Home Return (with home search)
Condition Direction Limit status Operation
Over limit input (+):ON
Table to move
Forward
Over limit input (-):ON
Table to move
Over limit input (+):ON
Table to move
When Home return is
turned ON
Reverse
Over limit input (-):ON
Table to move
Forward
Over limit input (+):ON
Automatic-reverse
operation
During Home return
operation
Reverse
Over limit input (-):ON
Automatic-reverse
operation

Table of Contents