EasyManua.ls Logo

Panasonic FPG-PP21

Panasonic FPG-PP21
240 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Home Return FP2 Positioning Unit
10-26
10.9 Special Mention
The time from the home input to the pulse output stop during the home return (home
search)
The FPPositioning unit performs the process in the very high speed, so that it starts counting the
number of the output pulses within 1µs from when the home input is ON. The time is always stable,
enabling the accurate home return (home search) operation. Since each axis is completely independent,
the home returns by the multiple axes at the same time are possible for the multiple-axis type.

Table of Contents

Other manuals for Panasonic FPG-PP21

Related product manuals