FPΣ Positioning Unit Fanctions of FPΣ Positioning Unit
1-7
1.3 Restrictions on Units Combination
1.3.1 Restrictions on Combinations Based on Current Consumption
The internal current consumption (at 5 V DC power supply) for the positioning units is noted below.
When the system is configured, the other units being used should be taken into consideration, and a
power supply unit with a sufficient capacity should be used.
Part number Product number Current consumption at 5 V DC
FPG-PP11 AFPG430 150mA
FPG-PP21 AFPG431 220mA
FPG-PP12 AFPG432 150mA
FPG-PP22 AFPG433 220mA
1.3.2 Restrictions on Unit Installation Position
Up to 4 of the positioning units can be installed to the left of the FP Control Unit. (Installing to the right
is unavailable.)
1.3.3 Restrictions on the Number of Units Installed
There are no restrictions on the number of units that may be installed, as long as the restrictions
described in 1.3.1 and 1.3.2 above are observed.