FP Positioning Unit P Point Control: Multi - Stage Acceleration / Deceleration
7-15
7.5 Operation at Over limit Input
P point control operation is as follows when Over limit input (+) or Over limit input (-) is ON.
Condition Direction Limit status Operation
Over limit input (+):ON
Table not to move,
Limit error occurs.
Forward
Over limit input (-):ON
Table not to move,
Limit error occurs.
Over limit input (+):ON
Table not to move,
Limit error occurs.
When P point
control is turned ON.
Reverse
Over limit input (-):ON
Table not to move,
Limit error occurs.
Forward Over limit input (+):ON
Table stops,
Limit error occurs.
During P point
control operation
Reverse Over limit input (-):ON
Table stops,
Limit error occurs.