FP Positioning Unit Wiring
3-3
3.1 Connecting using Connector for a Discrete-Wire
3.1.1 Specifications of Connector for Discrete-wire
This is a connector that allows loose wires to be connected without removing the wire’s insulation. The
pressure connection tool (AXY52000FP) is required to connect the loose wires.
Suitable wire (twisted wire)
Size Official cross section area Insulation thickness Rated current
AWG22 0.3mm
2
1.5 to 1.1 dia. 3A
AWG24 0.2mm
2
Discrete-wire connector (attached with a unit)
Manufacturer Component parts
Unit type and required quantit
2-axis type 4-axis type
Panasonic Electric
Works SUNX Co., Ltd.
Housing(40P) 1 pc x 1 1 pc x 2
Semi-cover(40P) 2 pcs x 1 2 pcs x 2
Contact (for AWG22 and AWG24) 5pin 8 pcs x 1 8 pcs x 2
* 1 connector set and 2 connector sets are supplied with the 2-axis type unit and 4-axis type unit,
respectively.
Dedicated tool
Manufacturer Product number
Panasonic Electric Works SUNX Co., Ltd. AXY52000FP