Code Function Set Value
Effective
Range
Default Remarks
523 Receive equalizer select
1: 0 km
2: 1.8 km
3: 3.6 km
4: 7.2 km
1~4 1 When the telephone station
is
from the unit or reception
cannot
performed correctly, adjust
accordingly.
524 Transmission equalizer
select
1: 0 km
2: 1.8 km
3: 3.6 km
4: 7.2 km
1~4 1 When the telephone station
is
from the unit or
transmission
be performed correctly,
adjust
accordingly.
550 Memory clear
See TEST FUNCTIONS ().
551 ROM check
See TEST FUNCTIONS ().
552 DTMF single tone test 1:ON 2:
OFF
1, 2 2
See TEST FUNCTIONS ().
553 Monitor on FAX
communication select
1:OFF 2:
PHASE B 3
:ALL
1~3 1 Sets whether to monitor
the
signal with the unit's
speaker
FAX communication or not.
554 Modem test
See TEST FUNCTIONS ().
555 Scan check
See TEST FUNCTIONS ().
556 Motor test 0
See TEST FUNCTIONS ().
558 LCD test
See TEST FUNCTIONS ().
559 Document jam detection
select
1:ON 2:
OFF
1, 2 1
See DOCUMENT JAMS -
SENDING
561 KEY test
See TEST FUNCTIONS ().
570 BREAK % select 1:61% 2:
67%
1, 2 1 Sets the % break of pulse
dialing
according PBX.
571 ITS auto redial time set X number
of times
00~99 05 Selects the number of
times
is redialed (not including
the
dial).
572 ITS auto redial line
disconnection time set
X second 001~999 065 Sets the interval of ITS
redialing.
573 Remote turn-on ring
number set
X number
of rings
01~99 10 Sets the number of rings
before
unit starts to receive a
document
the TEL mode.
590 FAX auto redial time set X number
of times
00~99 05 Selects the number of
redial
during FAX communication
(
including the first dial).
591 FAX auto redial time
disconnection time set
X second 001~999 065 Sets the FAX redial interval
during
FAX communication.
592 CNG transmit select
1:OFF
2:ALL
3:AUTO
1~3 2
Lets you select the CNG
output
during FAX transmission.
ALL
is output at phase A. AUTO:
output only when
automatic
performed. OFF: CNG id
not
phase A. Refer to
SOMETIME
IS A TRANSMIT PROBLEM ()