2.8 [1] Configuration
PC Programming Manual 121
Maintenance Console Location
2.8.4 [1-1] Slot—Card Property - Extension Type
Programming Manual References
None
Feature Guide References
None
DTMF-R STD Detection Time
Specifies the minimum length that a DTMF tone must be for the PBX to recognise it as a DTMF tone.
Value Range
2 × n (n=1–31) ms
Maintenance Console Location
2.8.4 [1-1] Slot—Card Property - Extension Type
Programming Manual References
None
Feature Guide References
None
SLT Power Supply (KX-TDA100/KX-TDA200/KX-TDA600 only)
Selects the voltage that enables an SLT to activate the Message Waiting lamp. This setting is only
available with MSLC/EMSLC cards.
Value Range
85 V, 145 V
Maintenance Console Location
2.8.4 [1-1] Slot—Card Property - Extension Type
Programming Manual References
None
Feature Guide References
1.19.1 Message Waiting
Optional Equipment (KX-TDA100/KX-TDA200/KX-TDA600 only)
Indicates whether an Extension Caller ID card is mounted on the SLC8 card (reference only). This is
only available with SLC8 cards.