EasyManua.ls Logo

Panasonic KX-TDA100

Panasonic KX-TDA100
854 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.8 [1] Configuration
334 PC Programming Manual
Maintenance Console Location
2.8.45 [1-1] Slot—Card Property - DPH type (KX-TDA30 only)
Programming Manual References
2.8.46 [1-1] Slot—Card Property - DPH type—Connection Command (KX-TDA30 only)
Feature Guide References
None
For Output (EIO)—Device Type
Selects the type of connected output device (for output ports only).
Value Range
Relay, Ringer, Door Opener (DPH4 only)
Maintenance Console Location
2.8.45 [1-1] Slot—Card Property - DPH type (KX-TDA30 only)
Programming Manual References
None
Feature Guide References
1.17.2 Door Open
1.17.10 External Relay Control
For Sensor (EIO)—Input Signal Decision Time
Specifies the minimum duration of continuous input from the triggered sensor before the PBX
recognises the input and makes a sensor call.
Value Range
32 × n (n=2–255) ms
Maintenance Console Location
2.8.45 [1-1] Slot—Card Property - DPH type (KX-TDA30 only)
Programming Manual References
None
Feature Guide References
1.17.9 External Sensor
For Sensor (EIO)—Input Signal Detection Reopening Time
Specifies the length of time after the sensor has been triggered during which any further input from
the sensor will be ignored.

Table of Contents

Other manuals for Panasonic KX-TDA100

Related product manuals