2.7 Connection of Extensions
2.7.1 Maximum Cabling Distances of the Extension Wiring
(Twisted Cable)
Cable Maximum Distance
ø 0.4 mm: 500 m
ø 0.5 mm: 720 m
ø 0.6 mm: 830 m
CAT 5: 720 m
Cable Maximum Distance
ø 0.4 mm: 500 m
ø 0.5 mm: 720 m
ø 0.6 mm: 830 m
CAT 5: 720 m
Cable Maximum Distance
ø 0.4 mm: 140 m
ø 0.5 mm: 229 m
ø 0.6 mm: 360 m
CAT 5: 229 m
Cable Maximum Distance
ø 0.4 mm: 698 m
ø 0.5 mm: 1128 m
ø 0.6 mm: 1798 m
CAT 5: 1128 m
DSS Console
SLT
KX-T7600 Series DPT
Cable Maximum Distance
ø 0.4 mm: 222 m
ø 0.5 mm: 347 m
ø 0.6 mm: 500 m
CAT 5: 347 m
PT-interface CS
KX-DT300 Series DPT
Notice
The maximum cabling distance may vary depending on the conditions.
PT-interface
CS
DPT DSS Console SLT
MCSLC24, MCSLC16 Cards
ü
DLC16, DLC8 Cards
ü ü ü
DLC4
Port on the DMPR Card
ü ü ü