2.7.2 Digital EXtra Device Port (Digital XDP) Connection
A DPT can be connected to another DPT on the Digital XDP connection.
Note
• Both DPTs must be KX-DT300/KX-T7600 series DPTs (except KX-T7640
). Note that the KX-T7667
can only be connected as a slave DPT.
• Bluetooth
®
Modules or USB Modules must not be connected to DPTs in the Digital XDP connection.
With KX-DT300 Series DPT
Using an EXtra Device Port
Master DPT Slave DPT
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
To DLC8/DLC16 card
To DLC4 port on the
DMPR card
Slave DPTMaster DPT
Cable Maximum Distance
ø 0.4 mm: 30 m
ø 0.5 mm: 50 m
ø 0.6 mm: 60 m
CAT 5: 50 m
Back View of DPTs
To DLC8/DLC16 card
To DLC4 port on the DMPR card
TO MAIN UNIT
/ PABX
TO MAIN UNIT
/ PABX
TO TEL
Installation Manual 117