2.6 Help
76 PC Programming Manual
Setting Features
A The following setting data is not saved to the SD memory card, so will be deleted when
the PBX is initialized. This data is stored in the PBX's battery backup memory.
Incoming Call Log
Outgoing Call Log (including Last Number Redial)
Message Waiting
•SMDR
ICD Group monitor log for supervisor
PBX date and time
Timed Reminder
LPR Timed Update time
Daily test start time
PT handset/headset volume
•PT SP-PHONE volume
PT ring volume
PT display contrast
ICD Group login status
(All extensions are set to Login by default.)
ICD Group Ready/Not Ready status
(All extensions are set to Ready by default.)
Live Call Screening (LCS) On/Off
Hands-free Answerback status
Absent Message status of extensions
(Absent Message data itself is not cleared.)
FWD/DND status
(FWD destinations are not cleared.)
Extension Dial Lock/Remote Extension Dial Lock
Extension PIN Lock/Extension PIN Lock counter
Verification Code PIN Lock/Verification Code PIN Lock counter
Password Lock counter for Remote System Programming
PBX Error Log
Digital Trunk Error Report data
In addition, the following data cannot be restored:
SVM Log and messages (both greeting messages and voice messages left by
callers) recorded in an SVM card (KX-TDA50 only)
Q
How do I change the dialing mode of an analog CO line?
A •From the 2.7.11 [1-1] Slot—LCO Port screen, change the Dialing Mode setting of the
target port to "DTMF" or "Pulse", as required.
Q
How do I set disconnect detection (CPC Detection) for an analog CO line?
A •From the 2.7.11 [1-1] Slot—LCO Port screen, modify the CPC Signal Detection
Time—Outgoing, Incoming setting of the target port.
The required value varies by carrier. Transmission and reception can be set separately.