Proxy Server Address
Description Specifies the IP address or FQDN of the proxy server.
Value Range Max. 127 characters
Note
You cannot leave this field empty if [Enable Proxy] is set to
[Yes].
Default Value Not stored.
Proxy Server Port
Description Specifies the port number of the proxy server.
Value Range 1–65535
Default Value 8080
4.3.5 Global Address Detection
This screen
allows you to configure the Global Address Detection feature and STUN server settings. The global
IP address of the network the unit is connected to will be detected periodically. If the global IP address has
changed, the new address will be registered to the SIP server.
Note
If the unit is connected directly to the Internet, or the network global address is static (i.e., does not
change), you do not need to configure Global Address Detection.
4.3.5.1 Global Address Detection
Detection Method
Description Selects the method to use for detecting the global IP address.
Value Range
STUN
SIP