Chapter 5Operations — Web control function
ENGLISH - 141
Contents of E-mail sent
Example of the E-mail sent when E-mail is set
The following E-mail is sent when the E-mail settings have been established.
=== Panasonic project or report (CO NF I GURE) ===
Project or T ype : RZ570
Serial No : 123456789012
----- E-mail setup data -----
TEMPERATURE WARNING SETUP
MI NIMUM T I ME at [ 60] minutes int erval
INTAKE AIR T EMPERAT URE O ver [ 31 degC / 87 degF ]
ERRO R [ O N ]
INTAKE AIR TEMPERATURE [ ON ]
PERIODIC REPORT
Sunday [ O N ] Monday [ O N ] T uesday [ ON ] Wednesday [ ON ]
T hursday [ ON ] F riday [ O N ] Saturday [ ON ]
00:00 [ O N ] 01:00 [ ON ] 02:00 [ ON ] 03: 00 [ ON ]
04:00 [ O N ] 05:00 [ ON ] 06:00 [ ON ] 07: 00 [ ON ]
08:00 [ O N ] 09:00 [ ON ] 10:00 [ ON ] 11: 00 [ ON ]
12:00 [ O N ] 13:00 [ ON ] 14:00 [ ON ] 15: 00 [ ON ]
16:00 [ O N ] 17:00 [ ON ] 18:00 [ ON ] 19: 00 [ ON ]
20:00 [ O N ] 21:00 [ ON ] 22:00 [ ON ] 23: 00 [ ON ]
----- check system -----
MAI N CPU BUS [ OK ]
FAN [ OK ]
INTAKE AIR TEMPERATURE [ OK ]
OPTICS MODULE TEMPERATURE [ OK ]
EXHAUST AIR TEMPERATURE [ OK ]
LIGHT TEMPERATURE1 [ OK ]
LIGHT TEMPERATURE2 [ OK ]
LIGHT STATUS [ OK ]
INTAKE AIR TEMP.SENSOR [ OK ]
OPTICS MODULE TEMP.SENSOR [ OK ]
EXHAUST AIR TEMP.SENSOR [ OK ]
LIGHT TEMP. 1 SENSOR [ OK ]
LIGHT TEMP. 2 SENSOR [ OK ]
BATTERY [ OK ]
COLOR WHEEL [ OK ]
BRIGHTNESS SENSOR [ OK ]
ANGLE SENSOR [ OK ]
ATM SENSOR [ OK ]
PHOSPHOR WHEEL [ OK ]
(Error code 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00)
Intake air temperature : 26 degC / 78 degF
O ptics module temperat ure : 35 degC / 95 degF
Exhaust air temperature : 30 degC / 86 degF
Light temperat ure1 : 44 degC / 111 degF
Light temperat ure2 : 33 degC / 91 degF
PRO JECT OR RUNTIME 16 H
PO WER ON 72 t imes
LIGHT RUNT IME 16 H
LIGHT O N 78 times
-------- Current status ---------
MAIN VERSION 1.00
SUB VERSION 1.00
LIGHT STATUS LIGHT=ON
INPUT CO MPUT ER1
SIGNAL NAME 1024x768
SIGNAL F REQ UENCY 48.22kHz / 59. 85Hz
----- Wired Network configuration -----
DHCP Client OFF
IP address 192.168. 0.8
MAC address 12:34: 56:78:90:12
Mon Jan 01 12: 34:56 20XX