Chapter 6 Maintenance — Light source/temperature indicators
148 - ENGLISH
Light source/temperature indicators
When an indicator lights up
If a problem occurs inside the projector, the light source indicator <LIGHT> or the temperature indicator <TEMP>
will inform you by lighting or blinking. Check the status of the indicators and take following measures.
Attention
f When switching off the projector to deal with problems, make sure to follow the procedure in “Switching off the projector” (x page 46).
Light source indicator <LIGHT>
Temperature indicator <TEMP>
Light source indicator <LIGHT>
Indicator status Lighting in red
Blinking in red
(2 times)
Blinking in red
(3 times)
Status
Some of the elements of the light
source are defective and the light
output has decreased.
The light source does not light up, or the light source turns off while the
projector is in use.
Cause ―
Solution
f Turn the <MAIN POWER> switch to <OFF> (x page 46), and turn on the power again.
Note
f If the light source indicator <LIGHT> continues to light or blink even after the measure is taken, set the <MAIN POWER> switch to <OFF>,
and ask your dealer for repair.
f The light source indicator <LIGHT> lights in green while the projector is in projection mode if there is no notication by lighting or blinking in
red.