F207 Frequency source selection
0: X;
1: X+Y;
2: X or Y (terminal
switchover);
3: X or X+Y (terminal
switchover);
4: Combination of
stage speed and
analog
5: X-Y
6: Reserved;
0 X
F208 Terminal operation mode
0: No function;
1: Two-line
operation mode 1;
2: Two-line
operation mode 2;
3: three-line
operation mode 1;
4: three-line
operation mode 2;
5: start/stop
controlled by
direction pulse
0 X
F209 Motor stopping mode
0: stop by
deceleration time;
1: free stop (coast
stop)
0 X
Function
Code
Function Denition Setting Range Mfr’s Value Change
10-5 Parameter List and Default Settings

Other manuals for Parker AC10 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC10 series and is the answer not in the manual?

Parker AC10 series Specifications

General IconGeneral
Overload Capacity150% for 60 seconds
Analog Inputs2
Analog Outputs1
Communication OptionsModbus RTU
Protection RatingIP20
Input Voltage200-240VAC, 380-480VAC, 500-575VAC, 600VAC, 690VAC
Digital Outputs2
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Operating Temperature-10°C to +50°C
Humidity5% to 95% (non-condensing)
DimensionsVaries by model
WeightVaries by model
BrakingBuilt-in dynamic braking