DOC-0017-04-EN: AC20 Series - Hardware Installation Manual
102 (154) DOC-0017-04-EN-A 22.03.2023
Application ‘3’: Presets
This is ideal for applications requiring multiple discrete speed levels.
The setpoint is selected from either the sum of the analogue inputs, (as in Application 1 and known here as
PRESET 0), or as one of up to seven other pre-defined speed levels. These are selected using DIN2, DIN3
and DIN4, refer to the Truth Table below.
The keypad can be used to re-define the speed levels of the PRESET 1 to PRESET 7 setpoints. Reverse
direction is achieved by entering a negative speed setpoint.
Configuration Setup:
RL1A
110-230Vac (or 24Vdc) voltage supply
RL1B
Healthy: Relay output (to lamp)
TH1
Motor Thermistor ‘+’ connection
TH2
Motor Thermistor ‘-’ connection
AI1
Remote Setpoint (%) input 1: 0-10V variable input (from potentiometer)
AI2
Remote Setpoint ‘Trim’ (%) input 2: 4-20mA variable input (from current source)
AO1
Speed Demand (%): 0-10V variable output (to voltmeter)
AO2
Value = 100%: 0-10V variable output (+10V fixed reference voltage)
DX1
Run Forward: 24V digital input
DX2
Preset Select 1: 24V digital input
DX3
Preset Select 2: 24V digital input
DI4
Preset Select 3: 24V digital input
DI5
Not Coast Stop: 24V digital input
STO
STO DISABLED (drive operational)
V
V
S