EasyManua.ls Logo

Parker AC20 Series - Page 35

Parker AC20 Series
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DOC-0017-04-EN: AC20 Series - Hardware Installation Manual
DOC-0017-04-EN-A 22.03.2023 35 (154)
Y-Capacitors & VDR Earth Disconnects
The AC20 products are fitted with EMC filter capacitors connected between ‘live’ AC Line (and in some
instances DC Link) circuits to earth. These capacitors are referred to as Y-Capacitors.
In some system applications where RCD’s are in circuit, or where the drive is connected on an IT supply,
these Y-Capacitors may need to be disconnected from earth. Removable links are provided to enable users
to perform this task.
By default:
- AC Line Y-Caps are connected to earth (‘EMC’ connector ‘J1’, is fitted in position 1 - 3).
- DC Link Y-Caps are connected to earth (‘P -> PE’ connector ‘J2’ is fitted in position 1 - 3).
Most products are also fitted with input line voltage suppression devices connected between ‘live’ AC Line
circuits to earth. These suppression devices are referred to as VDRs.
In some system applications where the product is exposed to large, transient voltage events on the power
supply that it is connected to, it is recommended that the VDRs are connected to earth as a means of
protecting the drives input rectification stage. Removable links are provided to enable users to perform this
task.
By default:
- VDRs are NOT connected to earth (‘VAR’ connector ‘Y1’, is fitted in position 2 - 4).
A summary of links fitted to each product is shown below:
1ø, 230V Products:
Frame
Size
Product Code
Motor
Power
(kW)
J1 ‘EMC’ (AC
Line Y-Cap)
Link:
Y1 ‘VAR’ (VDR)
Link:
J2 ‘P -> PE’ (DC
Link Y-Cap)
Link:
2
20G-12-0070...
1.5
x
x
20G-12-0100...
2.2
x
x
3ø, 230V Products:
Frame
Size
Product Code
Motor
Power
(kW)
J1 ‘EMC’ (AC
Line Y-Cap)
Link:
Y1 ‘VAR’ (VDR)
Link:
J2 ‘P -> PE’ (DC
Link Y-Cap)
Link:
2
20G-32-0070...
1.5
x
20G-32-0100...
2.2
x
3
20G-33-0170...
4.0
x
4
20G-34-0210...
5.5
x
x
5
20G-35-0300...
7.5
x
x
20G-35-0400...
11
x
x

Table of Contents