PCAN-Ethernet Gateway FD DR – User Manual
55
as well as the routes and filters are restored. The current
configuration is overwritten within that process.
Use the button on the left side to select a configuration file
(*. ini). To start the restoration process, click the Import button
located on the right.
Note: If you import a configuration file from another PCAN-
Gateway device that is in the same network, its IP address will
also be imported and loaded. Both devices would then have the
same IP address. This would cause an address conflict and
would result in both devices being non accessible. In such a
case, separate one device from the power supply. The other
device will then become accessible again and its IP address can
be changed manually. This will resolve the address conflict and
both devices can be used again.
Export Configuration:
With the Export button, you can download the current device
configuration and the defined routes and filters in the form of an ini
file.
The file can be freely renamed, the contents of the file however
should not be altered. Importing altered configuration files can lead
to failures during the import process. Only valid configuration files
can be used for device restoration.
Reload Default Settings:
With the Reload button, you can restore the device to its factory
defaults. During this process the login settings, all device and
communication interface settings along with existing routes will be
restored to the states they were in at the time of product delivery.
The current configuration is overwritten within that process. In
addition, the access data will be reset to the default values (see the