Installer manual Autotrol Magnum 293 - 298 Logix 742-762 - Description
14 / 110 Ref. MKT-IM-012 / D - 03.02.2022
3.2 Technical specifications
Design specifications/ratings
Valve body PPO Glass fiber reinforced
O-rings EPDM
Weight (valve with controller) 10.6kg
Recommended operating pressure 1.72 - 6.9bar
Water temperature 1- 38°C
Ambient temperature* 2- 50°C
Flow rates Magnum Cv (valve only)
Service at 1.03bar drop 17.3m
3
/h
Backwash at 1.72bar drop 20.2m
3
/h
Service Kv= 17m
3
/h (Cv= 19.5gpm)
Backwash Kv= 15.4m
3
/h (Cv= 17.8gpm)
Flow rates Magnum IT (valve only)
Service at 1.03bar drop 18.2m
3
/h
Backwash at 1.72bar drop 20.2m
3
/h
Service Kv= 17.94m
3
/h (Cv= 20.74gpm)
Backwash Kv= 15.4m
3
/h (Cv= 17.8gpm)
Valve connections
Tank Adapter Thread 4" – 8 UN
Inlet/Outlet Threads 1.5" Connections NPT or BSPT, Female,
CPVC
Drain line* 1 ½" Connections for NPT or BSPT, Female,
CPVC
Brine line ¾" NPT
Riser tube[Ø] 1 ½" O.D.
Riser installation Above top of tank 16mm ±3mm (⅝ ±⅛")
Pilot drain and auxiliary hydraulic
output
6.4mm (¼") tube fitting
* Valve installed drain flow controls available (1.14 - 9.08m
3
/h). If higher backwash flow is needed,
an external flow control will be required.
Electrical
Controller Operating Voltage 12VAC (requires use of Pentair Water supplied
transformer)
Input Supply Frequency 50 or60Hz (controller configuration dependent)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair AUTOTROL LOGIX 742 and is the answer not in the manual?

Pentair AUTOTROL LOGIX 742 Specifications

General IconGeneral
BrandPentair
ModelAUTOTROL LOGIX 742
CategoryControl Unit
LanguageEnglish

Related product manuals