Installer manual Autotrol Magnum 293 - 298 Logix 742-762 - Installation
42 / 110 Ref. MKT-IM-012 / D - 03.02.2022
5.5.2 Side-mounted valve installation
Use a 2" BSP side mount adapter assembly for the installation.
Side mount adapter
valid for location having a reduced height;
to avoid the piping supporting the valve and side adapter weight, they must be fixed on a
tripod or any other appropriate support;
in order to adequately compensate the tank elongation, the rubber expansion joints must be
mounted on the top and bottom of the tank.
Caution - material
Respect the heights given by the manufacturer.