Installer manual Autotrol Magnum 293 - 298 Logix 742-762 - Programming
Ref. MKT-IM-012 / D - 03.02.2022 51 / 110
6.3.3 Basic programming 742 - 762/298 valve type
6.3.3.1 Program valve type
Set your valve type through the options.
1. Use and to scroll though valve type choices.
ð Valve type flashes
2. Choose the 298 valve type.
3. Press to validate the valve type selected and advance to
the next parameter using or .
6.3.3.2 Program system size
Set your input system size and your resin volume in litres.
1. Use and to scroll though resin volume choices.
ð Three dashes than resin volume flashes.
2. Choose the nearest volume to your actual system size.
3. Press to validate the system size selected and advance to
the next parameter using or .
4. If an incorrect setting is programmed, see Resetting the
controller [
Page62].
6.3.3.3 Time setting
Set the current time.
1. Press when the time of the day is displayed.
ð Time flashes.
2. Adjust displayed time with and .
3. Press to validate the selection and advance to the next
parameter using or .
6.3.3.4 Day of week
Set the current day of the week.
1. Press .
ð Arrowflashes.
2. Adjust displayed time with and .
3. Press to validate the selection and advance to the next
parameter using or .