Installer Manual Fleck 5800 - XTR - Programming
Ref. MKT-IM-006 / B - 16.01.2018 65 / 122
Meter
Generic
0,1 - 999.9 pulses
per gallon
1 - 1500 pulses
per litre
Only available when generic meter type is
selected.
Continuous
flow detect
ON
OFF
If set ON, gives an alarm if continuous flow is
detected at the outlet.
Setting
review
Displays a summary of all programmed settings.
Remote
regeneration
Remote
signal
duration
1 - 255 seconds
OFF
Set the timing for contact closure in seconds
in order to trigger the regeneration.
Cl generation
Low salt
Cl generation
/
Low salt
OFF
ON
Low salt detect.
This parameter will not be available for filter
regeneration types.
On the valves of series 5800, cl generation/low
salt must be set OFF because the chlorine cell
kit managed by the XTR is not available for
those valves.
If set ON, chlorine generation together with
low salt detection will be performed during
brine draw cycle.
If set "Low salt detec.", only low salt detection
will be performed during brine cycle.
Regen
interval
1 - 255
Regeneration
Only available when cl generation/low salt is
set ON.
This parameter determines the regeneration
frequency on which there will be chlorine
generation.
Low salt detection will be performed during
regenerations indifferently of the frequency
set for cl generation.
Salt alarm will not avoid scheduled
regenerations to be performed.