Installer Manual Foleo - Programming
62 / 112 Ref. MKT-IM-038 / C - 15.11.2019
5.4.10. Chlorine generation screen
From the secondary master settings screen press the cl generation/low salt button to display the
chlorine generation screen.
cl generation/low salt: Set to on.
regen. interval: Contains the setting for the chlorine generation interval. Set up from 1 to 255 to
define the interval of regeneration between each chlorination activation, e.g. 1 so that it is enabled at
every regeneration or 10 so that it is activated every 10 regenerations for instance.
MANDATORY
To be programmed upon local regulation and inlet water quality. In case no information is
available, it is advised to set "regen interval" at 4.
MANDATORY
If bacterial growth issue is however noticed, reduce the interval.
Press to save and to return to the master settings screen or press to return to the master
settings screen without saving.
Chlorine Gen./Low Salt
cl generation/
low salt
on
regen. interval
4