EasyManua.ls Logo

Pentair FOLEO 5800 XTR - Injector and Injector Screen Cleaning

Pentair FOLEO 5800 XTR
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer Manual Foleo - Maintenance
80 / 112 Ref. MKT-IM-038 / C - 15.11.2019
8.5.4. Injector and injector screen cleaning
No. Operation
A
Remove the softener cover, see 8.5.1. First steps, page 76 and 8.5.2. Softener cover
removal, page 77.
B Remove the injector cap screws (3).
C Remove the injector cap (2).
D Remove the seal (4) taking note of its position.
E Using the injector puller (1), remove the injector (5).
CAUTION
To avoid any damage on the injector, use only the dedicated puller to remove it.
F Remove the screen (6).
G Clean or change the injector (5), the screen (6) and the seal (4).
H
Lubricate all seals with approved P-80
®
Emulsion lubricant only.
CAUTION
Using another type of lubricant, such as petroleum-based lubricants (Vaseline, oils, or
hydrocarbon-based lubricants) or silicone grease, may damage the valve.
I Reverse above procedure steps to rebuild.

Table of Contents