Installer Manual Foleo - Programming
44 / 112 Ref. MKT-IM-038 / C - 15.11.2019
5.3. Touchscreen controller quick start
NOTE
Press on any quick start screen to reset the screen back to its default settings, excepted
on the "Assistance interval" screen.
NOTE
Steps 5.3.2. and 5.3.3. are optional and are not required to start the system. All controller
settings may be changed after the unit is in service.
NOTE
If the screen is blank after plugging in the unit, touch the screen to turn the screen on.
Setting
review
Displays a summary of all programmed settings.
Water Saver
Regen
Water saver
regen.
Off
Remote
regeneration
Remote
signal
duration
Off
Cl generation
Low salt
Cl generation
/
Low salt
On
Chlorine generation together with low salt
detection will be performed during brine draw
cycle.
Regen
interval
1 - 255
Regeneration
This parameter determines the regeneration
frequency on which there will be chlorine
generation.
Low salt detection will be performed during
regenerations indifferently of the frequency
set for cl generation.
Salt alarm will not avoid scheduled
regenerations to be performed.
To be programmed upon local regulation and
inlet water quality. In case no information is
available, it is advised to set "Regen interval"
at 4.
If bacterial growth issue is however noticed,
reduce the interval.