Installer Manual Foleo - Maintenance
78 / 112 Ref. MKT-IM-038 / C - 15.11.2019
8.5.3. Brine tank, brine well, safety brine valve and air check cleaning
No. Operation
A
Remove the softener cover, see 8.5.1. First steps, page 76 and 8.5.2. Softener cover
removal, page 77.
B Turn the clips (11) 90 degrees, remove the cabinet plate and the brine well covers (4 + 10).
C
Remove the safety brine valve clip (7) and free the brine valve tube (5) from the safety
brine valve (6).
D Remove the brine tank (12) and brine well (8) from cabinet (3).
E Transfer the remaining salt from brine tank (12) to a basket.
CAUTION
Do not lay down or flip over the softener to empty the brine tank.
F
Remove the nut (9) and remove the safety brine valve (6) and the air check (13) from the
brine well (8).
G
Clean the brine tank (12), the brine well (8), the safety brine valve (6), the air check (13)
and the salt funnel (1) with water and sponges.
H Reverse above procedure steps to rebuild.
I Fill the brine tank (12) with salt, see 8.3. Adding salt, page 75.