Chapter 3: Configuring your PEC Plus Phason
30 2009-06-15
The PEC Plus starts counting time as soon as it is connected to an incoming power
supply.
To set the clock
1. Press Function until the LED for CONFIGURATION is lit.
2. Press Up or Down until (loc is displayed and then press Select.
The display shows the current time.
3. Press Up or Down to adjust the hours and then press Select.
4. Press Up or Down to adjust the minutes and then press Select.
The control saves the time and returns to the Configuration menu
5. Press Back to return to the main display.
Selecting the temperature units
Your PEC Plus can display temperatures in either degrees Fahrenheit (°F) or degrees Celsius (°C),
but not both at the same time. The factory default is °F.
If you want to change the temperature units, follow the steps below.
To select the temperature unit
1. Press Function until the LED for CONFIGURATION is lit.
2. Press Up or Down until un;t is displayed and then press Select.
The display shows the current temperature unit.
3. Press
Up or Down to toggle between °F and °C and then press
Select.
The control returns to the Configuration menu.
4. Press Back to return to the main display.
(loc
CONFIGURATION
1630
un;t
CONFIGURATION
!f