FL MGUARD RS4000 TX/TX-P
105656_en_05 PHOENIX CONTACT 135
6.10 Restart, recovery procedure, and flashing the firm-
ware
The reset button is used to set the device to one of the following states:
– Performing a restart
– Performing a recovery procedure
– Flashing the firmware/rescue procedure
Figure 6-6 Reset button
6.10.1 Performing a restart
Objective The device is restarted with the configured settings.
Action • Press the Reset button for around 1.5 seconds until the ERR LED lights up.
(Alternatively, disconnect the power supply and then connect it again.)