Description Display message
WHAT TO DO
- Press the ON/OFF key to shut the stove down.
- The alarm beep stops.
- The smoke motor remains active for 8 minutes and the display shows the message WAIT COOLING.
- This message is followed by EMPTY BRAZIER (see the table EMPTY BRAZIER”).
EMPTY
BRAZIER
1 2:0022
.
c
1
If the hopper has completely depleted the pellet supply while running and the smoke temperature
decreases, the message E7 appears on the display and the alarm beep sounds.
The stove reverts to alarm mode.
E7
1 2:0022
.
c
1
!
NO LIT
E9
1 2:0022
.
c
1
!
WHAT TO DO
- Press the ON/OFF key to shut the stove down.
- The beep stops.
- The smoke motor remains active for 8 minutes and the display shows the message WAIT COOLING.
- The message EMPTY BRAZIER will appear on the display.
- Load the pellet hopper (see paragraph PELLET LOADING”).
- Proceed as described in the “LOAD AUGER table and then follow the instructions of the EMPTY
BRAZIER table.
SHUT
DOWN
1 2:0022
.
c
1
EMPTY
BRAZIER
1 2:0022
.
c
1
If during start up the stove does not reach the start temperature limit within the specied time, the
message “NO LIT E14 appears and the alarm beep sounds.
The stove reverts to alarm mode.
1 2:0022
.
c
1
!
NO LIT
E14
WHAT TO DO
- Press the ON/OFF key to shut the stove down.
- The beep stops.
- Check the pellet load in the hopper and ll it if necessary (see paragraph “PELLET LOADING”).
- Make sure that the brazier is not obstructed with pellets or combustion residuals and clean if
necessary.
- If the problem persists please contact the Technical Assistance Centre.
SHUT
DOWN
1 2:0022
.
c
1
a Do not empty the brazier inside the hopper as there may still be unburnt pellets present.
a Any occasional start-up failure of the appliance may be caused by:
- incorrect composition or dimension of the pellet as described in this manual (see the chapter "FUEL");
- insufcient electrical power.
In the above cases, the intervention of a Support Centre is not to be considered under guarantee as it is not due to product defect.