Command Line Interface
89
Syntax description
on
Perform Integrity Check
off
No Integrity Check is performed
Default
off
E&M Wink Start Signaling Configuration Commands
The E&M wink start signaling configuration commands are used to define parameters specific to
E&M wink start interface. These commands apply to E&M Wink Start signaling protocol only.
set port port emw in_wink_digit_ignore
This command is used to specify the period of time that will be ignored after completing the wink
and before digits will be accepted for incoming calls.
set port port emw in_wink_digit_ignore milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging from 0 to 65535.
Default
30
set port port emw in_wink_dur
This command is used to specify the duration of the wink signal on the E-lead for incoming calls.
set port port emw in_wink_dur milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging from 0 to 65535.
Default
200
set port port emw in_wink_wait_max
This command is used to set the maximum delay before beginning the wink on the E-lead after de-
tecting a line seizure on the M-lead for an incoming call.
set port port emw in_wink_wait_max milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging from 0 to 65535.