2 - 9
ProCam Tests
ProCam tests should be performed in the following order:
Mandatory Tests
• Ambient Exposure at 100 C/FS
• Strobe Exposure (Graywall)
Additional test (s) required only if the strobe Exposure (Graywall) test reading
cannot be corrected by adjusting the IR Exposure Calibration slide:
• ZLS Graywall Test
If the ZLS Graywall Test is not within specification, replace the Strobe
Board or the Flashtube Assembly as required.
If the ZLS Graywall Test is within specification but the Strobe Exposure
(Graywall) reading remains out-of-specification, perform the Hybrid
Strobe/Blade Speed Test.
• Hybrid (Strobe/Blade Speed Test
If the Hybrid Test reading is within specification but the Strobe Exposure
Test reading remains out-of-specification, replace the Exposure Board and
then retest.
If the Hybrid Test reading is out-of-specification, perform the Hybrid Test
Adjustment.
If the Hybrid Adjustment fails to bring the reading within specification,
perform the Blade Speed Test.
• Blade Speed Test
If the Blade Speed is within specification but the strobe exposure Test
reading remains out-of-specification, replace the Exposure Board and then
retest.
If the Blade Speed Test reading is not within specification, perform the
Blade Speed Adjustment.
If the Blade Speed Test Adjustment does not correct Blade Speed, repair
or replace the Shutter Assembly and then retest.