2 - 4
Controls and Indicators
Table 2-1 lists and describes the controls and indicators of the model 12650-3
STAR Tester.
Table 2-1. STAR Tester Controls and Indicators
Key No. Control and Indicator Description
1 Disc Position Lamps Not Used.
2 RESET Pushbutton Clears electronics between tests.
3 TEST Selector Selects Test Mode (7000 ZLS, Flash
Exposure, Ambient and Blade Speed
for ProCam.
4 DISC/RIDE TIME Switch Selects disc catch or ride time mode
for ProCam.
5 HORN VOLTS Selector Selects 5V (Low), 6V (Nom), or
6.8V (High). Simulates film pack
battery voltage.
6 20V/2000V Selector With VOLT PROBE jack and DC
Voltmeter, allows use of Tester as
Voltmeter.
7 VOLT PROBE Jack For checking DC voltages in ProCam
under test, with standard probe.
8 STOPS ERROR Meter Digital readout for Ambient, Hybrid,
Strobe Exposure Tests.
9 ZLS Meter Digital readout of Strobe light output
in Zonal Lumen seconds.
10 J4 Connector * For future applications.
11 DISC DET Cable Accepts cable from 660 Disc Detect/
Ride Time Fixture.