2 - 16
Strobe Integrated Current and Strobe Charge Time Tests
Note: These tests are together because the ProCam and Tester settings are
the same. Both tests can be performed together for convenience.
The Strobe Integrated Current Test measures the energy required to fully charge
the strobe capacitor in the ProCam.
The Strobe Charge Time Test measures the maximum time required for strobe
recycling.
Setup
1. Using the Door Switch Activator tool, trip the door switch on the ProCam.
2. Place the ProCam on the Test Horn on top of the Tester.
3. Slide all switches on the ProCam into the down (on) position, except for
the AF.
4. Cover the Photocell on the ProCam.
5. Set the TEST selector to zls.
Test Procedure
1. Press the shutter button fully to fire the strobe.
2. After the strobe fires, slide the strobe switch on the ProCam down (OFF)
during the three (3) seconds that the blades are open (Maximum Time-out).
3. After the ProCam has cycled, press the RESET pushbutton on the Tester
and then slide the ProCam strobe switch up (ON).
4. Read the strobe current value on the DC CURRENT meter and the
maximum value displayed by the TIMING meter. Compare the readings to
the specifications.
5. If either the Strobe Integrated Current or the Strobe Charge Time readings
are not within specification, replace the Strobe Board.
Note: There are no adjustments for the Strobe Integrated Current or the
Strobe Charge Time.

Table of Contents

Other manuals for Polaroid ProCam

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polaroid ProCam and is the answer not in the manual?

Polaroid ProCam Specifications

General IconGeneral
BrandPolaroid
ModelProCam
CategoryFilm Camera
LanguageEnglish

Related product manuals