2 - 18
3. If the Ambient Exposure Test readings are to high, use a dental pick and slide
the Ambient Calibration Slide (Figure 2-5) to the left, in proportion to the
amount the reading is too high.
4. Put the Top Cover in place and then retest the ProCam. If necessary, re-adjust
the Ambient Calibration Slide.
5. When the Ambient Exposure Test reading is within specification, replace the
Top Cover.
Note: If adjusting the Ambient Calibration Slide fails to bring the readings
within specification, refer to the steps 3 through 5 of the Ambient
Exposure Test procedure on page 2-10.
IR Strobe Exposure Calibration Slide Adjustment
1. Remove the Top Cover from the ProCam.
Note: Reference the Disassembly and Assembly procedures in Section 3 of
this Service Manual to remove the Top Cover.
Caution: High Voltage Exposure! Voltages up to 320 volts are present
on the top flash tube terminal (Green wire) and at various
other locations on the Strobe Board.
2. If the Strobe Exposure Test readings are to low, use a dental pick and slide
the IR Strobe Calibration Slide (Figure 2-6) to the right, in proportion to the
amount the reading is too low.
Note: The IR Strobe Calibration Slide is the nearer or the front most slide,
when the Base Block is viewed from the rear of the ProCam.
3. If the Strobe Exposure Test readings are to high, use a dental pick and slide
the IR Strobe Calibration Slide (Figure 2-6) to the left, in proportion to the
amount the reading is too high.
4. Put the Top Cover in place and then retest the ProCam. If necessary, re-adjust
the IR Strobe Calibration Slide.