Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12
A - 60
Description
This parameter indicates the line voltage (in Volts) of the PSTN interface. The
value is valid in both on-hook and off-hook modes. The value can be positive
or negative, indicating the polarity of the tip/ring voltage. When the value
changes sign, it indicates that a polarity reversal has occurred.
Examples
pstn_loop_current
PSTN Loop Current
Description
This parameter indicates the loop current (in milliamps) of the PSTN interface.
The value is only valid when the interface is off-hook.
Virt Chans Mono
System Limits Minimum: -128, Maximum: 128
Event Source No
Argument Argument value
Command Response Description
get pstn_line_voltage
"Phone Out"
val pstn_line_voltage
"Phone Out" 0
Queries the pstn_line_voltage and returns the measured
value in Volts on the phone line "Phone Out". Note that
the phone out virtual channel name must be used, not the
phone in virtual channel name.
Argument Argument value
Channel Type Virtual Channel
Value Type Floating-Point
Read/Write Mode Read-Only
Phys Chans Analog Telephony Output
Virt Chans Mono
System Limits Minimum: 0.0, Maximum: 281.6, Resolution: 0.1
Event Source No

Table of Contents

Other manuals for Polycom SoundStructure C16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom SoundStructure C16 and is the answer not in the manual?

Polycom SoundStructure C16 Specifications

General IconGeneral
BrandPolycom
ModelSoundStructure C16
CategoryConference System
LanguageEnglish

Related product manuals