8
PORA ELECTRIC MACHINERY CO.,LTD.
Tension Controller
4) How to wire tension detector
Please connect accurately like below since the way of wiring is different according to the type of tension detector.
▶ PRTL (Loadcell): PRTL-A, PRTL-AB, PRTL-B, PRTL-C, PRTL-D, PRTL-E, PRTL-PA
▶ PR-LX (Pickup): PR-LX-030TD, PR-LX-050TD, PR-100TD
▶ PRTP (Differential pickup): PRTP-2T, PRTP-3T, PRTP-5T
34 363533323130
www.pora.com
PR-DTC-4100.
A
/
PR-DTC-4100.
AD
DIGITAL TENSION CONTROLLER
(PRTL-A, PRTL-AB, PRTL-B, PRTL-C, PRTL-D, PRTL-E, PRTL-PA)
LOAD CELL TYPE
51 / 56 52 / 57 53 / 58 54 / 59
RED
(적색)
WHT
(흰색)
GRN
(녹색)
BLU
(청색)
SENSOR INPUT 1
51 / 56 52 / 57 53 / 58 54 / 59
(PR-LX-030TD, PR-LX-050TD, PR-100TD)
LVDT PICK UP TYPE
RED
(적색)
BLK
(흑색)
GRN
(녹색)
WHT
(흰색)
SENSOR INPUT 1
30 / 34 31 / 35 32 / 36
BRW
(갈색)
BLU
(청색)
GRN
(녹색)
(PRTP-2T, PRTP-3T, PRTP-5T)
DIFFERENTIAL PICK UP TYPE
SENSOR INPUT 2
19 20 21 22 23 2524 26 27 28 29
ANALOG INPUT
+5V GND AI1+ AI1- AI2+ AI3+AI2- AI3- TG+ TG- FG
13 14 15 16 17 188 9 1110 121 2 3 5 64 7
DO1 DI1 DI2 DI4DI3 DI5 DI6 COM FG +24V SIG GNDDO2 DO3 DO4 DO5 DO6 COM
DIGITAL OUTPUT DIGITAL INPUT PRX
30 31 32 34 3533 36
PWM SIG3+ SIG3- FG PWM SIG4+ SIG4-
SENSOR INPUT2
49 5044 45 4746 4837 38 39 41 4240 43
RX GND LH R1 R2 FGVO1 GND IO1 VO2 GND IO2 TX
RS232
(Modbus-RTU)
ANALOG OUTPUT CAN
60 61 62 64 6563 66
51 52 53 5554 56 57 58 59
EXC1+ EXC1- SIG1+ SIG1- FG EXC2+ EXC2- SIG2+ SIG2-
SENSOR INPUT1
AC 100~240V
FUSE [ 1.6A ]
FUSE [ 7A ]
POWER S/W
DI1
8
DI2
9
DI3
10
DI4
11
DI5
12
DI6
13
COM
14
DIGITAL INPUT
DO1
1
DO2
2
DO3
3
DO4
4
DO5
5
DO6
6
COM
7
DIGITAL OUTPUT
PR-DTC-4100.AD ONLY
PA NA PB NB
POWDER BRAKE / POWDER CLUTCH
RED
WHITE
GREEN
BLUE
RED
WHITE
GREEN
BLUE
GROUND
Loadcell
(PRTL)
Sensor 1
Loadcell
(PRTL)
Sensor 2
Loadcell connection terminal
GREEN
GREEN
BROWN
BROWN
BLUE
BLUE
GROUND
64 66656362616055 5756 595854535251
www.pora.com
PR-DTC-4100.
A
/
PR-DTC-4100.
AD
DIGITAL TENSION CONTROLLER
(PRTL-A, PRTL-AB, PRTL-B, PRTL-C, PRTL-D, PRTL-E, PRTL-PA)
LOAD CELL TYPE
51 / 56 52 / 57 53 / 58 54 / 59
RED
(적색)
WHT
(흰색)
GRN
(녹색)
BLU
(청색)
SENSOR INPUT 1
51 / 56 52 / 57 53 / 58 54 / 59
(PR-LX-030TD, PR-LX-050TD, PR-100TD)
LVDT PICK UP TYPE
RED
(적색)
BLK
(흑색)
GRN
(녹색)
WHT
(흰색)
SENSOR INPUT 1
30 / 34 31 / 35 32 / 36
BRW
(갈색)
BLU
(청색)
GRN
(녹색)
(PRTP-2T, PRTP-3T, PRTP-5T)
DIFFERENTIAL PICK UP TYPE
SENSOR INPUT 2
19 20 21 22 23 2524 26 27 28 29
ANALOG INPUT
+5V GND AI1+ AI1- AI2+ AI3+AI2- AI3- TG+ TG- FG
13 14 15 16 17 188 9 1110 121 2 3 5 64 7
DO1 DI1 DI2 DI4DI3 DI5 DI6 COM FG +24V SIG GNDDO2 DO3 DO4 DO5 DO6 COM
DIGITAL OUTPUT DIGITAL INPUT PRX
30 31 32 34 3533 36
PWM SIG3+ SIG3- FG PWM SIG4+ SIG4-
SENSOR INPUT2
49 5044 45 4746 4837 38 39 41 4240 43
RX GND LH R1 R2 FGVO1 GND IO1 VO2 GND IO2 TX
RS232
(Modbus-RTU)
ANALOG OUTPUT CAN
60 61 62 64 6563 6651 52 53 5554 56 57 58 59
FG L NEXC1+ EXC1- SIG1+ SIG1- FG EXC2+ EXC2- SIG2+ SIG2-
SENSOR INPUT1 AC 100~240V
FUSE [ 1.6A ]
FUSE [ 7A ]
POWER S/W
DI1
8
DI2
9
DI3
10
DI4
11
DI5
12
DI6
13
COM
14
DIGITAL INPUT
DO1
1
DO2
2
DO3
3
DO4
4
DO5
5
DO6
6
COM
7
DIGITAL OUTPUT
PR-DTC-4100.AD ONLY
PA NA PB NB
POWDER BRAKE / POWDER CLUTCH
Differential pickup
(PRTP)
Sensor 1
Differential pickup
(PRTP)
Sensor 2
Differential pickup connection terminal
RED
BLACK
GREEN
WHITE
RED
BLACK
GREEN
WHITE
GROUND
34 363533323130
www.pora.com
PR-DTC-4100.
A
/
PR-DTC-4100.
AD
DIGITAL TENSION CONTROLLER
(PRTL-A, PRTL-AB, PRTL-B, PRTL-C, PRTL-D, PRTL-E, PRTL-PA)
LOAD CELL TYPE
51 / 56 52 / 57 53 / 58 54 / 59
RED
(적색)
WHT
(흰색)
GRN
(녹색)
BLU
(청색)
SENSOR INPUT 1
51 / 56 52 / 57 53 / 58 54 / 59
(PR-LX-030TD, PR-LX-050TD, PR-100TD)
LVDT PICK UP TYPE
RED
(적색)
BLK
(흑색)
GRN
(녹색)
WHT
(흰색)
SENSOR INPUT 1
30 / 34 31 / 35 32 / 36
BRW
(갈색)
BLU
(청색)
GRN
(녹색)
(PRTP-2T, PRTP-3T, PRTP-5T)
DIFFERENTIAL PICK UP TYPE
SENSOR INPUT 2
19 20 21 22 23 2524 26 27 28 29
ANALOG INPUT
+5V GND AI1+ AI1- AI2+ AI3+AI2- AI3- TG+ TG- FG
13 14 15 16 17 188 9 1110 121 2 3 5 64 7
DO1 DI1 DI2 DI4DI3 DI5 DI6 COM FG +24V SIG GNDDO2 DO3 DO4 DO5 DO6 COM
DIGITAL OUTPUT DIGITAL INPUT PRX
30 31 32 34 3533 36
PWM SIG3+ SIG3- FG PWM SIG4+ SIG4-
SENSOR INPUT2
49 5044 45 4746 4837 38 39 41 4240 43
RX GND LH R1 R2 FGVO1 GND IO1 VO2 GND IO2 TX
RS232
(Modbus-RTU)
ANALOG OUTPUT CAN
60 61 62 64 6563 66
51 52 53 5554 56 57 58 59
EXC1+ EXC1- SIG1+ SIG1- FG EXC2+ EXC2- SIG2+ SIG2-
SENSOR INPUT1
AC 100~240V
FUSE [ 1.6A ]
FUSE [ 7A ]
POWER S/W
DI1
8
DI2
9
DI3
10
DI4
11
DI5
12
DI6
13
COM
14
DIGITAL INPUT
DO1
1
DO2
2
DO3
3
DO4
4
DO5
5
DO6
6
COM
7
DIGITAL OUTPUT
PR-DTC-4100.AD ONLY
PA NA PB NB
POWDER BRAKE / POWDER CLUTCH
Pickup
(PR-LX)
Sensor 1
Pickup
(PR-LX)
Sensor 2
Pickup connection terminal
The color of connection terminal between tension detector for pickup type and for loadcell type is different.
Please be sure to check the above connection terminal to avoid malfunction and damage.
Caution:
Please check each type of connection terminal for tension detector.