18
PORA ELECTRIC MACHINERY CO.,LTD.
Tension Controller
PR-DTC-4100.A / AD
Alarm bit Alarm contents Detailed explanation
0 OVER INPUT L Input signal of left tension detector has exceeded the standard.
1 OVER INPUT R Input signal of right tension detector has exceeded the standard.
2 - -
3 UNBALANCE SPAN Left/right span values are imbalance more than 20%.
4 UNBALANCE TENSION Left/right tension values are imbalance more than 20%.
5 HIGH TENSION Tension values goes up more than upper limit of setting values.
6 LOW TENSION Tension values goes down less than lower limit of setting values
7 ZERO TENSION Tension value is 0kg.
8 OVERLOAD A Overload has occurred to A output of control shaft.
9 OVERLOAD B Overload has occurred to B output of control shaft.
10 OVERHEAT The driver board inside a product is overheating (more than 70℃ )
11 MAX DIAMETER Diameter operation has reached maximum values.
12 POWER ERROR The power (+12V, +12V, 5V) inside a product is unstable.
13 BAD CONN . L An error has occurred to wiring of left tension detector signal.
14 BAD CONN . R An error has occurred to wiring of right tension detector signal.
15 - -