EasyManua.ls Logo

PORA PR-DTC-4100.AD - Page 47

PORA PR-DTC-4100.AD
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
45
PORA ELECTRIC MACHINERY CO.,LTD.
PR-DTC-4100.A / AD
Setting menu item Submenu item
Modbus address
Setting range (Setting item) Initial setting Setting values
Int Hex
12. DIGITAL
OUTPUT
1. DIGITAL 1 40111 9CAF
AUTO, MANU, OUT ON/OFF, ZERO,
EMS, A/B, TENSION HI, TENSION
LOW, SENSOR ERR, TENSION ERR,
DIAMETER MAX
AUTO
2. DIGITAL 2 40112 9CB0
AUTO, MANU, OUT ON/OFF, ZERO,
EMS, A/B, TENSION HI, TENSION
LOW, SENSOR ERR, TENSION ERR,
DIAMETER MAX
MANU
3. DIGITAL 3 40113 9CB1
AUTO, MANU, OUT ON/OFF, ZERO,
EMS, A/B, TENSION HI, TENSION
LOW, SENSOR ERR, TENSION ERR,
DIAMETER MAX
OUT ON/OFF
4. DIGITAL 4 40114 9CB2
AUTO, MANU, OUT ON/OFF, ZERO,
EMS, A/B, TENSION HI, TENSION
LOW, SENSOR ERR, TENSION ERR,
DIAMETER MAX
ZERO
5. DIGITAL 5 40115 9CB3
AUTO, MANU, OUT ON/OFF, ZERO,
EMS, A/B, TENSION HI, TENSION
LOW, SENSOR ERR, TENSION ERR,
DIAMETER MAX
SENSOR ERR
6. DIGITAL 6 40116 9CB4
AUTO, MANU, OUT ON/OFF, ZERO,
EMS, A/B, TENSION HI, TENSION
LOW, SENSOR ERR, TENSION ERR,
DIAMETER MAX
TENSION ERR
13. FILTER
1. TENSION(sec) 40121 9CB9 0.1~10.0 1.0
2. ANALOG IN(sec) 40122 9CBA 0.1~10.0 0.3
3. ANALOG OUT(sec) 40123 9CBB 0.1~10.0 0.3
14. USER SET
1. OUTPUT HOLD 40131 9CC3 UNUSE, TENSION, LINESPEED UNUSE
2. REF.TENSION(% FS) 40132 9CC4 0.0~100.0 10.0
3. REF.SPEED(mpm) 40133 9CC5 0.0~1000.0 10.0
4. HOLD TIME(sec) 40134 9CC6 0.0~100.0 3.0
5. HOLD RATIO(%) 40135 9CC7 0.0~1000.0 100.0
6. EMS TIME(sec) 40136 9CC8 0.0~100.0 3.0
7. EMS RATIO(%) 40137 9CC9 0.0~1000.0 100.0
8. BUZZER 40138 9CCA UNUSE, USE USE
15. DISPLAY
1. TENSION DISPLAY 40141 9CCD TOTAL, LEFT, RIGHT TOTAL
2. DECIMAL POINT 40142 9CCE 1, 0.1, 0.01 0.1
3. L OFFSET(% FS) 40143 9CCF 0.0~100.0 0.0
4. L SPAN(xN) 40144 9CD0 0.0~10.0 1.0
5. R OFFSET(% FS) 40145 9CD1 0.0~100.0 0.0
6. R SPAN(xN) 40146 9CD2 0.0~10.0 1.0
7. BRIGHTNESS(%) 40147 9CD3 10.0~100.0 80.0
8. OUTPUT DISPLAY 40148 9CD4 %, V %
INPUT
Master
-> Slave (PORA)
Exclusive use for
writing
REMOTE INPUT 40191 9CFF Refer to Fieldbus Interface -
Target tension 40192 9D00 0~20000 [1kg, 1N] -
MANUAL OUTPUT 40193 9D01 0~1000 [0.1%] -
LINESPEED 40194 9D02 0~10000 [0.1mpm] -
DIAMETER 40195 9D03 0~20000 [0.1mm] -
OUTPUT
Slave (PORA)
-> Master
Exclusive use for
reading
Status output 40196 9D04 Refer to Fieldbus Interface -
TOTAL TENSION 40197 9D05 -20000~20000 [1kg, 1N] -
LEFT TENSION 40198 9D06 -20000~20000 [1kg, 1N] -
RIGHT TENSION 40199 9D07 -20000~20000 [1kg, 1N] -
CONTROL OUTPUT 40200 9D08 0~1000 [0.1%] -
1. Data setting using communication does not support data type for Float. Please set ‘int type’ which multiplies 10
from current data for all read/write of Float type data.
2. When setting data, please input only within relevant setting range.
※Caution

Related product manuals