45
PORA ELECTRIC MACHINERY CO.,LTD.
PR-DTC-4100.A / AD
Setting menu item Submenu item
Modbus address
Setting range (Setting item) Initial setting Setting values
Int Hex
12. DIGITAL
OUTPUT
1. DIGITAL 1 40111 9CAF
AUTO, MANU, OUT ON/OFF, ZERO,
EMS, A/B, TENSION HI, TENSION
LOW, SENSOR ERR, TENSION ERR,
DIAMETER MAX
AUTO
2. DIGITAL 2 40112 9CB0
AUTO, MANU, OUT ON/OFF, ZERO,
EMS, A/B, TENSION HI, TENSION
LOW, SENSOR ERR, TENSION ERR,
DIAMETER MAX
MANU
3. DIGITAL 3 40113 9CB1
AUTO, MANU, OUT ON/OFF, ZERO,
EMS, A/B, TENSION HI, TENSION
LOW, SENSOR ERR, TENSION ERR,
DIAMETER MAX
OUT ON/OFF
4. DIGITAL 4 40114 9CB2
AUTO, MANU, OUT ON/OFF, ZERO,
EMS, A/B, TENSION HI, TENSION
LOW, SENSOR ERR, TENSION ERR,
DIAMETER MAX
ZERO
5. DIGITAL 5 40115 9CB3
AUTO, MANU, OUT ON/OFF, ZERO,
EMS, A/B, TENSION HI, TENSION
LOW, SENSOR ERR, TENSION ERR,
DIAMETER MAX
SENSOR ERR
6. DIGITAL 6 40116 9CB4
AUTO, MANU, OUT ON/OFF, ZERO,
EMS, A/B, TENSION HI, TENSION
LOW, SENSOR ERR, TENSION ERR,
DIAMETER MAX
TENSION ERR
13. FILTER
1. TENSION(sec) 40121 9CB9 0.1~10.0 1.0
2. ANALOG IN(sec) 40122 9CBA 0.1~10.0 0.3
3. ANALOG OUT(sec) 40123 9CBB 0.1~10.0 0.3
14. USER SET
1. OUTPUT HOLD 40131 9CC3 UNUSE, TENSION, LINESPEED UNUSE
2. REF.TENSION(% FS) 40132 9CC4 0.0~100.0 10.0
3. REF.SPEED(mpm) 40133 9CC5 0.0~1000.0 10.0
4. HOLD TIME(sec) 40134 9CC6 0.0~100.0 3.0
5. HOLD RATIO(%) 40135 9CC7 0.0~1000.0 100.0
6. EMS TIME(sec) 40136 9CC8 0.0~100.0 3.0
7. EMS RATIO(%) 40137 9CC9 0.0~1000.0 100.0
8. BUZZER 40138 9CCA UNUSE, USE USE
15. DISPLAY
1. TENSION DISPLAY 40141 9CCD TOTAL, LEFT, RIGHT TOTAL
2. DECIMAL POINT 40142 9CCE 1, 0.1, 0.01 0.1
3. L OFFSET(% FS) 40143 9CCF 0.0~100.0 0.0
4. L SPAN(xN) 40144 9CD0 0.0~10.0 1.0
5. R OFFSET(% FS) 40145 9CD1 0.0~100.0 0.0
6. R SPAN(xN) 40146 9CD2 0.0~10.0 1.0
7. BRIGHTNESS(%) 40147 9CD3 10.0~100.0 80.0
8. OUTPUT DISPLAY 40148 9CD4 %, V %
INPUT
Master
-> Slave (PORA)
Exclusive use for
writing
REMOTE INPUT 40191 9CFF Refer to Fieldbus Interface -
Target tension 40192 9D00 0~20000 [1kg, 1N] -
MANUAL OUTPUT 40193 9D01 0~1000 [0.1%] -
LINESPEED 40194 9D02 0~10000 [0.1mpm] -
DIAMETER 40195 9D03 0~20000 [0.1mm] -
OUTPUT
Slave (PORA)
-> Master
Exclusive use for
reading
Status output 40196 9D04 Refer to Fieldbus Interface -
TOTAL TENSION 40197 9D05 -20000~20000 [1kg, 1N] -
LEFT TENSION 40198 9D06 -20000~20000 [1kg, 1N] -
RIGHT TENSION 40199 9D07 -20000~20000 [1kg, 1N] -
CONTROL OUTPUT 40200 9D08 0~1000 [0.1%] -
1. Data setting using communication does not support data type for Float. Please set ‘int type’ which multiplies 10
from current data for all read/write of Float type data.
2. When setting data, please input only within relevant setting range.
※Caution