44 Adjustment Procedures
Belt, Platen Open, Adjustment (Figure 42 )
1. Prepare the printer for maintenance (page 42).
2. Open the printer cover.
3. Remove the platen open belt cover (1) by squeezing the top and bottom
to release the plastic tabs from the slots in the side plate.
4. Loosen the motor mount screws (2).
5. Close the forms thickness lever all the way.
CAUTION
Too much tension on the platen open belt can cause the platen gap to
change, which can lead to premature wear of the platen, damaged
hammer tips, and poor print quality.
6. Using a force gauge, apply 10
± 1 pounds of tension to the platen open
motor shaft (3), pulling away from the large platen pulley.
7. Reduce tension to 5
± 1 pounds and torque the motor mount screws (2)
to 11
± 2 inchpounds.
8. Check the platen gap (page 414). Loosen the belt and readjust the gap
if necessary.
9. Snap the platen open belt cover (1) into the slots in the side plate.
10. Return the printer to normal operation (page 422).