9. You can enter the desired mass concentration using the
[Arrow keys]
.
CAUTION!
– Observe the decimal point.
–
The mass concentration is affected by both
changes in the stroke rate and the stroke length.
The value in the continuous display cannot be freely
changed using the [Arrow keys] as the least significant
figure values changes in jumps, the value of which
depends on the input data.
Possible values of the adjustable variables
Adjustable variable Lower value Upper value Increment
Flow in m
3
/h
1 1000 1
Mass concentration in % 0.5 100 0.1
Density in kg/l 0.5 2.0 0.1
10.6.1.2 BATCH operating mode (Settings for the "Concentration" function)
PP
P
P
P
Continuous
display
P
Concentration
Batch
off
on
P
Settings
Batch
Batch
Concentration
Auxiliar
Calibration
P
Main
Batch
Mode
Settings
Security
Clear
P
Concentration
Batch
7 l
35.0 %
1.26 kg/l
P
Concentration
Batch
7 l
35.0 %
1.26 kg/l
The "Concentration input" in
‘BATCH’
operating mode, is intended for
metering a substance into a storage tank so that it then exists in the con‐
tainer with a defined mass concentration (batching of a solution. Do not
forget to stir!).
n the medium in the storage tank has the same density as water (1 kg/L
≜ g/cm
3
)
n the mass concentration of the feed chemical is known - see the feed
chemical safety data sheet (e.g. with 35 % sulphuric acid: 35 %)
The prerequisites are that:
Set up
50