16 Technical data
16.1
Performance data
Liquid end type Minimum pump capacity
at maximum back pressure
Minimum pump capacity
at medium back pressure
bar l/h ml/stroke bar l/h ml/stroke
2508 25 7.5 0.62 12.5 8.0 0.67
1608 16 7.8 0.62 8 8.2 0.69
1612 16 11.3 0.94 8 12.2 1.02
1020 10 19.1 1.59 5 19.2 1.6
0730 7 29.2 2.43 3.5 29.4 2.45
0450 4 49.0 4.08 2 51.5 4.29
0280 2 75.0 6.25 1 75.6 6.3
Design with self-bleeding dosing head without bypass ***
1608 16 3.8 0.32 8 6.0 0.50
1612 16 6.5 0.54 8 11.1 0.93
1020 10 14.0 1.17 5 16.4 1.73
0730 7 28.0 2.33 3.5 30.9 2.58
Liquid end type Max. stroke
rate
Connector
size
3
outside Æ x
inside Æ
Suction lift* Priming lift** Permissible
priming pres‐
sure suction
side
Weight
Strokes/min mm m WS m WS bar kg
2508 200
8x4
1
5
3.5 / 3.0
2
8
10 / 11
2
1608 200 8x5 5
3.5 / 3.0
2
8
10 / 11
2
1612 200 8x5 6
3.0 / 2.5
2
8
10 / 11
2
1020 200 12x9 5
3.5 / 3.0
2
5
10 / 11
2
0730 200 12x9 5
4.0 / 3.5
2
3
10 / 11
2
0450 200 DN 10 3
2.5 / 2.5
2
2
10 / 11
2
0280 200 DN 10 2
3.0 / 3.0
2
1
10 / 11
2
Design with self-bleeding dosing head without bypass ***
1608 200 8x5 - 1.8 8 10
1612 200 8x5 - 1.8 8 10
1020 200 12x9 - 1.8 5 10
0730 200 12x9 - 1.8 3 10
delta
®
b operating at 200 strokes/minute
and 100 % stroke length
Technical data
85

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent delta DLTa optoDrive and is the answer not in the manual?

ProMinent delta DLTa optoDrive Specifications

General IconGeneral
BrandProMinent
Modeldelta DLTa optoDrive
CategoryWater Pump
LanguageEnglish

Related product manuals