16 Technical data
16.1
Performance data
Liquid end type Minimum pump capacity
at maximum back pressure
Minimum pump capacity
at medium back pressure
bar l/h ml/stroke bar l/h ml/stroke
2508 25 7.5 0.62 12.5 8.0 0.67
1608 16 7.8 0.62 8 8.2 0.69
1612 16 11.3 0.94 8 12.2 1.02
1020 10 19.1 1.59 5 19.2 1.6
0730 7 29.2 2.43 3.5 29.4 2.45
0450 4 49.0 4.08 2 51.5 4.29
0280 2 75.0 6.25 1 75.6 6.3
Design with self-bleeding dosing head without bypass ***
1608 16 3.8 0.32 8 6.0 0.50
1612 16 6.5 0.54 8 11.1 0.93
1020 10 14.0 1.17 5 16.4 1.73
0730 7 28.0 2.33 3.5 30.9 2.58
Liquid end type Max. stroke
rate
Connector
size
3
outside Æ x
inside Æ
Suction lift* Priming lift** Permissible
priming pres‐
sure suction
side
Weight
Strokes/min mm m WS m WS bar kg
2508 200
8x4
1
5
3.5 / 3.0
2
8
10 / 11
2
1608 200 8x5 5
3.5 / 3.0
2
8
10 / 11
2
1612 200 8x5 6
3.0 / 2.5
2
8
10 / 11
2
1020 200 12x9 5
3.5 / 3.0
2
5
10 / 11
2
0730 200 12x9 5
4.0 / 3.5
2
3
10 / 11
2
0450 200 DN 10 3
2.5 / 2.5
2
2
10 / 11
2
0280 200 DN 10 2
3.0 / 3.0
2
1
10 / 11
2
Design with self-bleeding dosing head without bypass ***
1608 200 8x5 - 1.8 8 10
1612 200 8x5 - 1.8 8 10
1020 200 12x9 - 1.8 5 10
0730 200 12x9 - 1.8 3 10
delta
®
b operating at 200 strokes/minute
and 100 % stroke length
Technical data
85