Module/
slot
Index Name Module
name
Identifi‐
cation
(hex)
Type Data
flow *
Description
3 Contact Pump is metering
volume in the
predefined time
R, W 4 Analog Pump is metering
in accordance
with the analogue
signal and ana‐
logue mode set
on the pump.
17 Manual
(con‐
centr.)
Manual in con‐
centration mode
18 Batch
(con‐
centr.)
Batch in concen‐
tration mode
19 Contact
(con‐
centr.)
Contact in con‐
centration mode
20 Analog
(con‐
centr.)
Analogue in con‐
centration mode
4 1 Nominal
flow
rate
Flow
rate
C0,83,8
3
f32 S Capacity setpoint in litres / hour
2 Actual
flow
rate
f32 R Actual capacity value
5 1 Max.
flow
rate
Max.
flow
rate
40.83 f32 R Maximum capacity in litres / hour
6 1 Batch
volume
Batch C0,83,8
8
f32 S Batch metering volume
2 Batch
time
u16 Time in which the batch is to be
metered
3 Batch
start
u8 If the value changes from 1 to 0,
batch metering is activated in batch
mode. (Batches may also be acti‐
vated via the contact input.)
4 Batch
memory
u8 If "Batch Memory" is activated and a
new batch is activated during a batch
metering already in progress, the
remaining metering volume is
increased by that of the new batch. If
the "Batch Memory" is not activated,
the remaining volume is deleted and
the new batch started.
5 Remaini
ng
volume
f32 R The remaining volume to be metered
in batch mode
7 1 Contact
volume
Con‐
tact
80.84 f32 S Volume metered per contact
Supplementary Operating Instructions for PROFINET
®
68