105
Managing with WebPAM PROeVess A3340 Product Manual
reDunDancy check
Redundancy Check is a routine maintenance procedure for fault-tolerant disk arrays (those with redundancy)
that ensures all the data matches exactly. Redundancy Check can also correct inconsistencies.
Note
You can use the scheduler to set up a Redundancy Check
Schedule.
To set up a schedule, click the menu expander to the right of
the Scheduler tab and select Redundancy Check Schedule.
Redundancy Check Rate
To change Redundancy Check Rate setting the in Background Activities Settings menu:
1. Click the Redundancy Check Rate drop-down menu and choose a rate:
• Low – Fewer system resources to Redundancy Check,
more to data read/write operations.
• Medium – Balances system resources between Redundancy
Check and data read/write operations.
• High – More system resources to Redundancy Check,
fewer to data read/write operations.
2. Click the Submit button.